Technical data KA450

Zeisberg GmbH

Technical data KA450

  • 2 channel tone and speech audiometer

  • Class 2 tone audiometer according to DIN EN 60645-1

  • Class B-E speech audiometer according to DIN EN 60645-1 with free-field equalization for DD45 air receiver

  • 13 frequencies from 125 Hz to 8 kHz, optional up to 20 kHz

    • 125 Hz, 250 Hz, 500 Hz, 750 Hz, 1000 Hz, 1500 Hz, 2000 Hz, 3000 Hz, 4000 Hz, 6000 Hz 8000 Hz

  • Damping selectable "off", "manual" or "synchronous" to the test tone with

    • Narrowband noise for the specified audiometric frequencies

    • Broadband noise

    • Speech masking noise

  • 4 converter connections for

    • Air duct

    • Bone conduction

    • Free field

    • Aux (tweeter, plug-in headphones, ...)

  • Signal modulation

    • Pure tone

    • Pulse tone

    • Wobble tone for free field

  • Integrated Freiburg language test on memory card

    • Randomized single word selection

    • Randomized group selection

    • Speech counter with evaluation of intelligibility and discrimination loss

  • Signal input for voice tests from CD or PC (audioApp: voice from hard disk)

  • Tone-In-Noise Test / Langenbeck noise audiometry

    • Superimposition of the test tone on the test tube

    • Narrowband or broadband noise

    • on all transducer outputs: Air, bone conduction, in free field and on Aux

  • Speech-In-Noise Test

    • Superimposition of the speech signal on the test ear

    • Speech masking or broadband noise

    • on all transducer outputs: Air, bone conduction, in free field and on Aux

  • Suprathreshold tests

    • SISI

    • Lüscher

    • Fowler (ABLB)

    • Stenger

    • Langenbeck with narrowband noise

    • Carhart (Tone Decay)

    • Tinnitus determination

      • with pure tones

      • with narrowband noise

      • Masking curve with narrowband noise or broadband noise

  • Large, ergonomic control unit

    • Membrane keypad with closed surface

    • Good disinfectability

    • 2 high-quality, mechanically mounted rotary controls for level control

      • right / left ear

      • Stimulus / anesthesia

    • Optional LED matrix

  • Integrated free-field amplifier

  • Integrated patient communication

    • Built-in intercom microphone for examiner

    • Connection for examiner headset

    • Connection for patient microphone

  • Galvanically isolated USB interface, no isolating transformer required

  • incl. accessories